燃煤电厂湿法脱硫后湿饱和烟气的直接排放一般会造成湿烟羽现象。对烟气加热法、烟气冷凝法、冷凝再热法和膜回收烟气水分法4种湿烟羽消除技术机理进行理论分析,利用湿烟羽预测模型定量计算了4种湿烟羽消除技术的参数选择。结果表明:烟气加热法,当环境温度低于5℃,相对湿度大于40%时,烟气需要加热至100℃以上;烟气冷凝法,当环境温度低于0℃,环境相对湿度大于40%时,需要将烟气冷凝低于15.5℃;烟气冷凝再热法的冷凝温度越低,再热温度就越低,当环境温度高于5℃,烟气冷凝至40℃,再热温度不高于80℃;膜回收法,当环境温度大于15℃、水回收率达到40%时,基本无白烟产生,而环境温度低于5℃时,水回收率要达到60%以上。
![1.jpg](http://img01.mybjx.net/news/UploadFile/202002/6371771655239270475605053.jpg)
![2.jpg](http://img01.mybjx.net/news/UploadFile/202002/6371771655240270535605053.jpg)
![3.jpg](http://img01.mybjx.net/news/UploadFile/202002/6371771655239970515605053.jpg)
![4.jpg](http://img01.mybjx.net/news/UploadFile/202002/6371771655248871026576869.jpg)
![5.jpg](http://img01.mybjx.net/news/UploadFile/202002/6371771655249971085104286.jpg)
![6.jpg](http://img01.mybjx.net/news/UploadFile/202002/6371771655250071095104286.jpg)
![7.jpg](http://img01.mybjx.net/news/UploadFile/202002/6371771655268172133818673.jpg)
![8.jpg](http://img01.mybjx.net/news/UploadFile/202002/6371771655271472315575335.jpg)